TitleProduct

Explosion-proof Electric Ball Valve

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shandong

  • Validity to:

    Long-term effective

  • Last update:

    2023-07-30 18:44

  • Browse the number:

    372

Send an inquiries
+
Shandong Beihua Environmental Protection Co., Ltd
Contactaixin:

beihuahuanbao(Mr.)  

Email:

telephone:

phone:

Arrea:

Shandong

Address:

Tang Cun Zhen Qiantang Community, Zoucheng City, Jining City, Shandong Province, China

Website:

http://www.sdbhhb.com/ http://beihuahuanbao.020taotao.com/

+

The valve interior is designed to take advantage of advanced innovative technology: Models DN25-DN80 use a durable all-in-one elastomaterials elastic assembly that includes a flexible rubber diaphragm with reinforced fibers and a high strength disc made of vulcanized material. External support diaphragm balance is good, there will be no deformation phenomenon, solenoid valve unique ball body in line with the fluid dynamics design, small resistance, over flow, small head loss. The cover can be removed by removing only four fastening bolts for quick online inspection and maintenance. Ensures proper operation of the elastic assembly, helping to achieve long-term valve operation and maintain excellent control performance even in harsh operating conditions. A diaphragm and spring can fully meet the valve operating pressure needs. Diaphragm assembly can be easily removed from body without removing valve from line.

The electromagnetic control valve works smoothly, without vibration noise and pressure fluctuation when switching. The pressure balance is perfectly supported regardless of the open or closed state. Sealed tightly, working pressure is 0.5~16 kg, suitable for a wide range of pressure. Suitable for various flow and pressure ranges.

The main valve uses the valve pressure difference to move the disc diaphragm assembly to open or close the valve. The pressure behind the valve in the next path acts below the diaphragm to cushion the closing force of the valve (the water flow in this path varies with the pressure difference and flows in the direction behind the valve). The pressure of the control chamber changes with the state of the regulating pilot valve and the fixed guide hole. The change in pressure causes the valve to open or close accordingly.

 

Working Principle

410 type electromagnetic control valve opens the electromagnetic head according to the control signal, so that the water in the signal tube enters the upper chamber of the valve through the solenoid valve, and the valve is closed after the upper chamber is filled with water. When the solenoid valve is closed, the upper chamber is drained, the valve is opened, and the normally closed solenoid valve acts on the contrary

 

Specification Parameter

 

Pressure

0.01bar

0.015bar

0.02bar

0.03bar

0.04bar

0.05bar

0.06bar

0.08bar

0.1bar

0.15bar

0.2bar

0.3bar

0.4bar

0.5bar

0.6bar

0.8bar

1bar

 

Dimension

flow

DN25

3m³

4m³

5m³

7m³

9m³

10m³

12m³

13m³

14m³

17m³

18m³

22m³

27m³

31m³

36m³

40m³

43m³

hour

DN30

3m³

4m³

5m³

7m³

9m³

10m³

12m³

13m³

14m³

17m³

18m³

22m³

27m³

31m³

36m³

40m³

43m³

hour

DN40

6m³

7m³

8m³

10m³

12m³

13m³

14m³

17m³

18m³

22m³

27m³

31m³

36m³

40m³

43m³

45m³

58m³

hour

DN50

6m³

7m³

8m³

10m³

12m³

13m³

14m³

17m³

18m³

22m³

27m³

31m³

36m³

40m³

43m³

45m³

58m³

hour

DN65

8m³

10m³

12m³

14m³

16m³

18m³

20m³

22m³

25m³

30m³

35m³

45m³

50m³

58m³

60m³

70m³

80m³

hour

DN80

13m³

17m³

19m³

22m³

27m³

30m³

32m³

38m³

41m³

50m³

60m³

71m³

82m³

95m³

100m³

110m³

130m³

hour

http://www.sdbhhb.com/